The MPM Wood Plus 26 This is a modern wood gasification boiler with a nominal output of 26 kW for logs. It meets the requirements of class 5 according to PN-EN 303-5 as well as the Ecodesign Directive and achieves energy efficiency class A+. Ideal for single-family homes with a buffer storage tank.
Highlights/Advantages
⭐ 26 kW nominal power – ideal for single-family homes and commercial units
⭐ 5th grade & Ecodesign – low emissions and high environmental compatibility
⭐ Energy efficiency class A+ (EEI 116) – economical operation
⭐ Large loading chamber (~120 dm³) – long burning time up to approx. 6 hours
⭐ Operation possible in an open or closed system
Detailed description
Area of application & Target audience
The MPM Wood Plus 26 is a log wood gasification boiler For use in open or closed heating systems according to PN-EN 12828. It is suitable for single-family homes, smaller apartment buildings, workshops and commercial units.
The operation is exclusively with a Buffer storage tank of at least 1000 liters prescribed.
Everyday benefits
The wood gasification principle involves combustion in two separate chambers – degassing of the wood and subsequent clean afterburning in the ceramic combustion chamber.
The result:
The large loading chamber (~120 dm³) allows for comfortable log lengths and reduces refueling intervals.
Technology & equipment
The boiler is manufactured as a welded steel construction and features:
-
movable cast iron grate
-
ceramic burner
-
vertical heat exchanger channels with turbulence unit
-
mechanical train regulator
-
Secondary air control
-
Thermometer in the upper area
Manual loading is done with firewood (moisture content ≤25%).
Recommended operating temperature: 60–90 °C
Minimum return temperature: 55 °C
Efficiency & Environment
The MPM Wood Plus 26 meets the Ecodesign Regulation (EU) 2015/1189 as well as the 5th grade according to PN-EN 303-5:2021-09.
Seasonal energy efficiency: 79%
Energy efficiency class: A+
EEI: 116
Emissions at rated power:
-
PM: 15 mg/m³
-
OGC: 10 mg/m³
-
CO: 398 mg/m³
-
NOx: 142 mg/m³
This means the boiler meets the current requirements for modern biomass heating systems.
compatibility & System integration
It can be operated in both open and closed heating systems.
Maximum operating pressure: 1.5 bar
Required chimney draft: approx. 0.30 mbar
For continuous operation, a return flow boost (e.g., a 3- or 4-way mixing valve) is recommended.
Technical data
| feature | Value |
| Manufacturer | MPM Project Marcin Nykiel |
| Model | Wood Plus 26 |
| Product type | wood gasification boiler |
| Nominal heating output | 26 kW |
| Energy efficiency class | A+ |
| Energy Efficiency Index (EEI) | 116 |
| Seasonal energy efficiency | 79% |
| boiler class | 5th class (PN-EN 303-5:2021-09) |
| Thermal efficiency at rated power | 82.3% |
| heating surface | 2.9 m² |
| Water volume | 94 dm³ |
| Loading chamber volume | approx. 120 dm³ |
| Burning time | approx. 6 h |
| Fuel consumption | 7 kg/h |
| Exhaust gas temperature | 125–140 °C |
| Exhaust gas mass flow | 15 g/s |
| Max. operating pressure | 1.5 bar |
| Operating temperature | 60–90 °C |
| Minimum return temperature | 55 °C |
| Height | 1183 mm |
| Wide cases | 600 mm |
| Total width | 655 mm |
| Total length | 1220 mm |
| Weight | approx. 450 kg |
| Connection flow/return | 40 mm |
| Minimum buffer storage | 1000 liters |
Scope of delivery
Accessories/Recommendation
For optimal operation, we recommend:
-
Buffer storage tank ≥ 1000 liters
-
Thermal mixing valve (return temperature increase 55 °C)
-
Safety group with DBV-1 valve
-
Draft regulator for the chimney
-
Suitable stratified storage tank for domestic hot water
You can find suitable products in the section Buffer storage, Security groups and Heating accessories on gemashop.de.
Assembly & Safety instructions
Installation must be carried out exclusively by a qualified specialist company.
The boiler must be operated with a buffer storage tank.
The return temperature must not fall below 55 °C, otherwise corrosion damage and loss of warranty are likely.
FAQ
1. What type of fuel can the MPM Wood Plus 26 be operated with?
Using firewood (hardwood) with a moisture content ≤25%.
2. Is a buffer storage tank required?
Yes, at least 1000 liters are required.
3. What efficiency class does the boiler achieve?
A+ with an EEI of 116.
4. Is operation in a closed system permitted?
Yes, if professionally installed with a safety valve and thermal insulation.
5. What is the minimum return temperature required?
At least 55 °C.
6. What emission class does the boiler meet?
Class 5 according to PN-EN 303-5:2021-09 and Ecodesign.