{"product_id":"attack-slx-35-profi-holzvergaser-35-kw","title":"Wood gasifier 35 kW ATTACK SLX 35 Profi","description":"\u003cp data-start=\"352\" data-end=\"743\"\u003eThe \u003cstrong data-start=\"356\" data-end=\"379\"\u003eATTACK SLX 35 PROFI\u003c\/strong\u003e This is a high-performance wood gasification boiler with a nominal output of 35 kW for the efficient and low-emission combustion of logs. It is ideally suited for larger single-family homes, apartment buildings, or buildings with increased heating requirements. The tested emission and performance values ​​according to EN 303-5 confirm a standard-compliant and economical heating solution.\u003c\/p\u003e  \u003chr data-start=\"745\" data-end=\"748\"\u003e  \u003ch2 data-start=\"750\" data-end=\"774\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"776\" data-end=\"1140\"\u003e⭐  \u003cstrong data-start=\"778\" data-end=\"800\"\u003e35 kW nominal power\u003c\/strong\u003e – ideal for large living spaces\u003cbr data-start=\"832\" data-end=\"835\"\u003e⭐  \u003cstrong data-start=\"837\" data-end=\"864\"\u003eEfficiency up to 90.3%\u003c\/strong\u003e – efficient energy utilization of firewood\u003cbr data-start=\"909\" data-end=\"912\"\u003e⭐  \u003cstrong data-start=\"914\" data-end=\"949\"\u003eCertified according to EN 303-5:2012\u003c\/strong\u003e – tested emission values\u003cbr data-start=\"975\" data-end=\"978\"\u003e⭐  \u003cstrong data-start=\"980\" data-end=\"1009\"\u003eRobust steel construction\u003c\/strong\u003e – durable and reliable technology\u003cbr data-start=\"1047\" data-end=\"1050\"\u003e⭐  \u003cstrong data-start=\"1052\" data-end=\"1095\"\u003eTurbulator system with cleaning lever\u003c\/strong\u003e – easy maintenance and high heat transfer\u003c\/p\u003e  \u003chr data-start=\"1142\" data-end=\"1145\"\u003e  \u003ch1 data-start=\"1147\" data-end=\"1187\"\u003eATTACK SLX 35 PROFI wood gasifier 35 kW\u003c\/h1\u003e  \u003ch2 data-start=\"1189\" data-end=\"1219\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1221\" data-end=\"1360\"\u003eThe ATTACK SLX 35 PROFI is a \u003cstrong data-start=\"1253\" data-end=\"1302\"\u003eHot water boiler for solid fuels (wood)\u003c\/strong\u003e With manual loading. It is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"1362\" data-end=\"1532\"\u003e  \u003cli data-start=\"1362\" data-end=\"1389\"\u003e  \u003cp data-start=\"1364\" data-end=\"1389\"\u003elarge detached houses\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1390\" data-end=\"1412\"\u003e  \u003cp data-start=\"1392\" data-end=\"1412\"\u003eApartment buildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1413\" data-end=\"1466\"\u003e  \u003cp data-start=\"1415\" data-end=\"1466\"\u003eagricultural or commercial outbuildings\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1467\" data-end=\"1532\"\u003e  \u003cp data-start=\"1469\" data-end=\"1532\"\u003eRenovation projects with a sufficiently sized chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"1534\" data-end=\"1614\"\u003eThe preferred fuel type is \u003cstrong data-start=\"1568\" data-end=\"1613\"\u003eLogs with a moisture content ≤ 25%\u003c\/strong\u003e.\u003c\/p\u003e  \u003chr data-start=\"1616\" data-end=\"1619\"\u003e  \u003ch2 data-start=\"1621\" data-end=\"1642\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"1644\" data-end=\"1862\"\u003eThe wood gasification principle ensures a two-stage combustion process with high energy yield. First, the wood is gasified, then the wood gases are combusted at high temperatures. This produces:\u003c\/p\u003e  \u003cul data-start=\"1864\" data-end=\"2000\"\u003e  \u003cli data-start=\"1864\" data-end=\"1891\"\u003e  \u003cp data-start=\"1866\" data-end=\"1891\"\u003estable power output\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1892\" data-end=\"1924\"\u003e  \u003cp data-start=\"1894\" data-end=\"1924\"\u003eefficient fuel use\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1925\" data-end=\"1963\"\u003e  \u003cp data-start=\"1927\" data-end=\"1963\"\u003ereduced CO and dust emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"1964\" data-end=\"2000\"\u003e  \u003cp data-start=\"1966\" data-end=\"2000\"\u003econsistent heat supply\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2002\" data-end=\"2119\"\u003eThe integrated turbulator lever allows for regular cleaning of the heat exchanger without complex disassembly.\u003c\/p\u003e  \u003chr data-start=\"2121\" data-end=\"2124\"\u003e  \u003ch2 data-start=\"2126\" data-end=\"2150\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cul data-start=\"2152\" data-end=\"2517\"\u003e  \u003cli data-start=\"2152\" data-end=\"2196\"\u003e  \u003cp data-start=\"2154\" data-end=\"2196\"\u003eBoiler type: Wood gasification hot water boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2197\" data-end=\"2231\"\u003e  \u003cp data-start=\"2199\" data-end=\"2231\"\u003eFuel feed: manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2232\" data-end=\"2273\"\u003e  \u003cp data-start=\"2234\" data-end=\"2273\"\u003eAdjustable primary and secondary air\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2274\" data-end=\"2312\"\u003e  \u003cp data-start=\"2276\" data-end=\"2312\"\u003eFan-assisted combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2313\" data-end=\"2350\"\u003e  \u003cp data-start=\"2315\" data-end=\"2350\"\u003eTurbulators in the tube heat exchanger\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2351\" data-end=\"2394\"\u003e  \u003cp data-start=\"2353\" data-end=\"2394\"\u003eThermal safety device required\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2395\" data-end=\"2426\"\u003e  \u003cp data-start=\"2397\" data-end=\"2426\"\u003eMaximum operating pressure: 2.5 bar\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2427\" data-end=\"2482\"\u003e  \u003cp data-start=\"2429\" data-end=\"2482\"\u003eMinimum chimney diameter: 150 mm (200 mm recommended)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2483\" data-end=\"2517\"\u003e  \u003cp data-start=\"2485\" data-end=\"2517\"\u003eRecommended chimney draft: 23–30 Pa\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2519\" data-end=\"2652\"\u003eTo ensure a long service life, a return temperature above 65 °C must be maintained. Recommended boiler operating temperature: 80–85 °C.\u003c\/p\u003e  \u003chr data-start=\"2654\" data-end=\"2657\"\u003e  \u003ch2 data-start=\"2659\" data-end=\"2680\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"2682\" data-end=\"2792\"\u003eThe ATTACK SLX 35 PROFI meets the requirements of \u003cstrong data-start=\"2736\" data-end=\"2753\"\u003eEN 303-5:2012\u003c\/strong\u003e for boilers of fuel class A.\u003c\/p\u003e  \u003cp data-start=\"2794\" data-end=\"2835\"\u003eMeasurement values ​​according to certificate (rated power):\u003c\/p\u003e  \u003cul data-start=\"2837\" data-end=\"2985\"\u003e  \u003cli data-start=\"2837\" data-end=\"2865\"\u003e  \u003cp data-start=\"2839\" data-end=\"2865\"\u003eNominal heat output: 35 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2866\" data-end=\"2899\"\u003e  \u003cp data-start=\"2868\" data-end=\"2899\"\u003eMinimum heat output: 17.5 kW\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2900\" data-end=\"2924\"\u003e  \u003cp data-start=\"2902\" data-end=\"2924\"\u003eEfficiency: 90.3%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2925\" data-end=\"2953\"\u003e  \u003cp data-start=\"2927\" data-end=\"2953\"\u003eCO at 13% O₂: 79 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2954\" data-end=\"2985\"\u003e  \u003cp data-start=\"2956\" data-end=\"2985\"\u003eDust at 13% O₂: 11 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2987\" data-end=\"3074\"\u003eThe emission and performance values ​​were confirmed by an accredited testing laboratory.\u003c\/p\u003e  \u003chr data-start=\"3076\" data-end=\"3079\"\u003e  \u003ch2 data-start=\"3081\" data-end=\"3118\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"3120\" data-end=\"3219\"\u003eFor standard-compliant and efficient operation, the SLX 35 PROFI is usually combined with:\u003c\/p\u003e  \u003cul data-start=\"3221\" data-end=\"3354\"\u003e  \u003cli data-start=\"3221\" data-end=\"3239\"\u003e  \u003cp data-start=\"3223\" data-end=\"3239\"\u003eBuffer storage\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3240\" data-end=\"3279\"\u003e  \u003cp data-start=\"3242\" data-end=\"3279\"\u003eReturn flow booster\/mixing device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3280\" data-end=\"3311\"\u003e  \u003cp data-start=\"3282\" data-end=\"3311\"\u003eThermal safety device\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3312\" data-end=\"3333\"\u003e  \u003cp data-start=\"3314\" data-end=\"3333\"\u003eSafety valve\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3334\" data-end=\"3354\"\u003e  \u003cp data-start=\"3336\" data-end=\"3354\"\u003eExpansion vessel\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3356\" data-end=\"3467\"\u003eSuitable \u003cstrong data-start=\"3365\" data-end=\"3426\"\u003eBuffer storage tanks, return temperature boosts and safety groups\u003c\/strong\u003e You can find them in our product range at gemashop.de.\u003c\/p\u003e  \u003chr data-start=\"3469\" data-end=\"3472\"\u003e  \u003ch2 data-start=\"3474\" data-end=\"3493\"\u003eTechnical data\u003c\/h2\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"3495\" data-end=\"4009\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"3495\" data-end=\"3513\"\u003e  \u003ctr data-start=\"3495\" data-end=\"3513\"\u003e  \u003cth data-start=\"3495\" data-end=\"3505\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"3505\" data-end=\"3513\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"3533\" data-end=\"4009\"\u003e  \u003ctr data-start=\"3533\" data-end=\"3563\"\u003e  \u003ctd data-start=\"3533\" data-end=\"3546\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"3546\" data-end=\"3563\" data-col-size=\"sm\"\u003eATTACK s.r.o.\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3564\" data-end=\"3589\"\u003e  \u003ctd data-start=\"3564\" data-end=\"3573\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"3573\" data-end=\"3589\" data-col-size=\"sm\"\u003eSLX 35 PROFI\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3590\" data-end=\"3636\"\u003e  \u003ctd data-start=\"3590\" data-end=\"3603\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"3603\" data-end=\"3636\" data-col-size=\"sm\"\u003eWood gasification hot water boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3637\" data-end=\"3683\"\u003e  \u003ctd data-start=\"3637\" data-end=\"3650\" data-col-size=\"sm\"\u003efuel\u003c\/td\u003e  \u003ctd data-start=\"3650\" data-end=\"3683\" data-col-size=\"sm\"\u003eWood (Class A according to EN 303-5)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3684\" data-end=\"3713\"\u003e  \u003ctd data-start=\"3684\" data-end=\"3704\" data-col-size=\"sm\"\u003eNominal heat output\u003c\/td\u003e  \u003ctd data-start=\"3704\" data-end=\"3713\" data-col-size=\"sm\"\u003e35 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3714\" data-end=\"3748\"\u003e  \u003ctd data-start=\"3714\" data-end=\"3737\" data-col-size=\"sm\"\u003eMinimum heat output\u003c\/td\u003e  \u003ctd data-start=\"3737\" data-end=\"3748\" data-col-size=\"sm\"\u003e17.5 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3749\" data-end=\"3774\"\u003e  \u003ctd data-start=\"3749\" data-end=\"3764\" data-col-size=\"sm\"\u003eefficiency\u003c\/td\u003e  \u003ctd data-start=\"3764\" data-end=\"3774\" data-col-size=\"sm\"\u003e90.3%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3775\" data-end=\"3806\"\u003e  \u003ctd data-start=\"3775\" data-end=\"3794\" data-col-size=\"sm\"\u003eCO (at 13% O₂)\u003c\/td\u003e  \u003ctd data-start=\"3794\" data-end=\"3806\" data-col-size=\"sm\"\u003e79 mg\/m³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3807\" data-end=\"3841\"\u003e  \u003ctd data-start=\"3807\" data-end=\"3829\" data-col-size=\"sm\"\u003eDust (at 13% O₂)\u003c\/td\u003e  \u003ctd data-start=\"3829\" data-end=\"3841\" data-col-size=\"sm\"\u003e11 mg\/m³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3842\" data-end=\"3874\"\u003e  \u003ctd data-start=\"3842\" data-end=\"3863\" data-col-size=\"sm\"\u003eMaximum operating pressure.\u003c\/td\u003e  \u003ctd data-start=\"3863\" data-end=\"3874\" data-col-size=\"sm\"\u003e2.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3875\" data-end=\"3912\"\u003e  \u003ctd data-start=\"3875\" data-end=\"3902\" data-col-size=\"sm\"\u003eMinimum chimney diameter\u003c\/td\u003e  \u003ctd data-start=\"3902\" data-end=\"3912\" data-col-size=\"sm\"\u003e150 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3913\" data-end=\"3948\"\u003e  \u003ctd data-start=\"3913\" data-end=\"3936\" data-col-size=\"sm\"\u003eRecommended chimney draft\u003c\/td\u003e  \u003ctd data-start=\"3936\" data-end=\"3948\" data-col-size=\"sm\"\u003e23 Pa\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3949\" data-end=\"3984\"\u003e  \u003ctd data-start=\"3949\" data-end=\"3973\" data-col-size=\"sm\"\u003eFuel feed\u003c\/td\u003e  \u003ctd data-start=\"3973\" data-end=\"3984\" data-col-size=\"sm\"\u003emanually\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"3985\" data-end=\"4009\"\u003e  \u003ctd data-start=\"3985\" data-end=\"3992\" data-col-size=\"sm\"\u003estandard\u003c\/td\u003e  \u003ctd data-start=\"3992\" data-end=\"4009\" data-col-size=\"sm\"\u003eEN 303-5:2012\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"4011\" data-end=\"4014\"\u003e  \u003ch2 data-start=\"4016\" data-end=\"4031\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"4033\" data-end=\"4114\"\u003e  \u003cli data-start=\"4033\" data-end=\"4069\"\u003e  \u003cp data-start=\"4035\" data-end=\"4069\"\u003eATTACK SLX 35 PROFI wood gasifier\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4070\" data-end=\"4093\"\u003e  \u003cp data-start=\"4072\" data-end=\"4093\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4094\" data-end=\"4114\"\u003e  \u003cp data-start=\"4096\" data-end=\"4114\"\u003eAssembly instructions\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"4116\" data-end=\"4119\"\u003e  \u003ch2 data-start=\"4121\" data-end=\"4154\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cp data-start=\"4156\" data-end=\"4258\"\u003eInstallation and commissioning must only be carried out by a qualified specialist company.\u003c\/p\u003e  \u003cp data-start=\"4260\" data-end=\"4278\"\u003eImportant instructions:\u003c\/p\u003e  \u003cul data-start=\"4280\" data-end=\"4511\"\u003e  \u003cli data-start=\"4280\" data-end=\"4332\"\u003e  \u003cp data-start=\"4282\" data-end=\"4332\"\u003eThermal safety device absolutely necessary\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4333\" data-end=\"4399\"\u003e  \u003cp data-start=\"4335\" data-end=\"4399\"\u003eReturn temperature boost necessary to prevent condensation\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4400\" data-end=\"4437\"\u003e  \u003cp data-start=\"4402\" data-end=\"4437\"\u003eCompliance with chimney requirements\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4438\" data-end=\"4511\"\u003e  \u003cp data-start=\"4440\" data-end=\"4511\"\u003eRegular cleaning of ash box, turbulators and heat exchangers\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4513\" data-end=\"4581\"\u003eThe warranty may be limited if the installation is improper.\u003c\/p\u003e  \u003chr data-start=\"4583\" data-end=\"4586\"\u003e  \u003ch2 data-start=\"4588\" data-end=\"4594\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"4596\" data-end=\"4689\"\u003e\u003cstrong data-start=\"4596\" data-end=\"4650\"\u003e1. What performance does the ATTACK SLX 35 PROFI offer?\u003c\/strong\u003e\u003cbr data-start=\"4650\" data-end=\"4653\"\u003eThe nominal heat output is 35 kW.\u003c\/p\u003e  \u003cp data-start=\"4691\" data-end=\"4795\"\u003e\u003cstrong data-start=\"4691\" data-end=\"4732\"\u003e2. Which fuels are permitted?\u003c\/strong\u003e\u003cbr data-start=\"4732\" data-end=\"4735\"\u003eFirewood with a maximum moisture content of 25%, 12–20% recommended.\u003c\/p\u003e  \u003cp data-start=\"4797\" data-end=\"4878\"\u003e\u003cstrong data-start=\"4797\" data-end=\"4834\"\u003e3. What is the efficiency?\u003c\/strong\u003e\u003cbr data-start=\"4834\" data-end=\"4837\"\u003eThe tested efficiency is 90.3%.\u003c\/p\u003e  \u003cp data-start=\"4880\" data-end=\"4989\"\u003e\u003cstrong data-start=\"4880\" data-end=\"4922\"\u003e4. Does the boiler comply with EN 303-5?\u003c\/strong\u003e\u003cbr data-start=\"4922\" data-end=\"4925\"\u003eYes, it meets the requirements of EN 303-5:2012 for Class A.\u003c\/p\u003e  \u003cp data-start=\"4991\" data-end=\"5119\"\u003e\u003cstrong data-start=\"4991\" data-end=\"5034\"\u003e5. Is a buffer storage tank required?\u003c\/strong\u003e\u003cbr data-start=\"5034\" data-end=\"5037\"\u003eA buffer storage tank is recommended for efficient and compliant operation.\u003c\/p\u003e  \u003cp data-start=\"5121\" data-end=\"5257\"\u003e\u003cstrong data-start=\"5121\" data-end=\"5165\"\u003e6. How often is cleaning necessary?\u003c\/strong\u003e\u003cbr data-start=\"5165\" data-end=\"5168\"\u003eEmpty the ash box daily, and clean the heat exchanger and turbulators regularly according to the operating instructions.\u003c\/p\u003e  \u003chr data-start=\"5259\" data-end=\"5262\"\u003e  \u003ch2 data-start=\"5264\" data-end=\"5272\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"5274\" data-end=\"5582\"\u003eThe \u003cstrong data-start=\"5278\" data-end=\"5307\"\u003eATTACK SLX 35 PROFI 35 kW\u003c\/strong\u003e This is a high-performance wood gasifier for larger buildings with increased heating requirements. Certified emission values ​​and robust technology make it a reliable solution for sustainable heating with logs. Order now and rely on proven wood gasifier technology.\u003c\/p\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49418334110044,"sku":"ASLXP35","price":3632.22,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/SLXprofi-webrender.webp?v=1774512395","url":"https:\/\/mt.gemashop.de\/fi\/products\/attack-slx-35-profi-wood-carburettor-35-kw-2","provider":"GEMA Shop","version":"1.0","type":"link"}