{"product_id":"mpm-wood-plus-14-holzvergaserkessel-14kw","title":"MPM Wood Plus 14 wood gasification boiler 14 kW log boiler","description":"\u003cp data-start=\"937\" data-end=\"1293\"\u003eThe MPM Wood Plus 14 is a modern wood gasification boiler with a nominal output of 14 kW for the efficient combustion of logs. It meets the requirements of Class 5 according to PN-EN 303-5:2021-09 as well as the Ecodesign Directive and achieves energy efficiency class A+.\u003cbr data-start=\"1206\" data-end=\"1209\"\u003eIdeal for single-family homes and smaller commercial units with buffer storage operation.\u003c\/p\u003e  \u003chr data-start=\"1295\" data-end=\"1298\"\u003e  \u003ch2 data-start=\"1300\" data-end=\"1324\"\u003eHighlights\/Advantages\u003c\/h2\u003e  \u003cp data-start=\"1326\" data-end=\"1721\"\u003e⭐ Wood gasification technology – efficient, clean combustion of firewood\u003cbr data-start=\"1402\" data-end=\"1405\"\u003e⭐ Energy efficiency class A+ (EEI 118) – reduced emissions and high efficiency\u003cbr data-start=\"1489\" data-end=\"1492\"\u003e⭐ Class 5 according to PN-EN 303-5:2021-09 – meets current environmental requirements\u003cbr data-start=\"1566\" data-end=\"1569\"\u003e⭐ Large filling chamber (~52 dm³) – comfortable burning time of up to approx. 5 hours\u003cbr data-start=\"1640\" data-end=\"1643\"\u003e⭐ Operation possible in open or closed systems – flexibly deployable\u003c\/p\u003e  \u003chr data-start=\"1723\" data-end=\"1726\"\u003e  \u003ch1 data-start=\"1728\" data-end=\"1765\"\u003eMPM Wood Plus 14 wood gasification boiler\u003c\/h1\u003e  \u003ch2 data-start=\"1767\" data-end=\"1797\"\u003eArea of ​​application \u0026amp; Target audience\u003c\/h2\u003e  \u003cp data-start=\"1799\" data-end=\"2025\"\u003eThe MPM Wood Plus 14 is a water-bearing wood gasification boiler with manual feeding for operation with logs (moisture content ≤ 25%). It is designed for open and closed heating systems and is particularly suitable for:\u003c\/p\u003e  \u003cul data-start=\"2027\" data-end=\"2135\"\u003e  \u003cli data-start=\"2027\" data-end=\"2048\"\u003e  \u003cp data-start=\"2029\" data-end=\"2048\"\u003eSingle-family homes\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2049\" data-end=\"2073\"\u003e  \u003cp data-start=\"2051\" data-end=\"2073\"\u003esmaller residential properties\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2074\" data-end=\"2135\"\u003e  \u003cp data-start=\"2076\" data-end=\"2135\"\u003eWorkshops, commercial pavilions and service businesses\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2137\" data-end=\"2229\"\u003eThe maximum flow temperature is 90 °C at a permissible operating pressure of 1.5 bar.\u003c\/p\u003e  \u003cp data-start=\"2231\" data-end=\"2436\"\u003eThe unit is designed for use exclusively with a buffer storage tank. According to the product data sheet, a buffer volume of at least 800 liters is required; 300–800 liters are technically recommended.\u003c\/p\u003e  \u003chr data-start=\"2438\" data-end=\"2441\"\u003e  \u003ch2 data-start=\"2443\" data-end=\"2464\"\u003eEveryday benefits\u003c\/h2\u003e  \u003cp data-start=\"2466\" data-end=\"2689\"\u003eThe wood gasification principle involves combustion in two separate chambers: First, the wood is degassed, then the resulting wood gases are combusted in a ceramic combustion chamber. This ensures:\u003c\/p\u003e  \u003cul data-start=\"2691\" data-end=\"2790\"\u003e  \u003cli data-start=\"2691\" data-end=\"2714\"\u003e  \u003cp data-start=\"2693\" data-end=\"2714\"\u003estable combustion\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2715\" data-end=\"2739\"\u003e  \u003cp data-start=\"2717\" data-end=\"2739\"\u003ehigh energy yield\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2740\" data-end=\"2765\"\u003e  \u003cp data-start=\"2742\" data-end=\"2765\"\u003ereduced emissions\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"2766\" data-end=\"2790\"\u003e  \u003cp data-start=\"2768\" data-end=\"2790\"\u003eclean exhaust gas routing\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"2792\" data-end=\"2954\"\u003eThe large loading chamber with a volume of approximately 52 dm³ allows for a burning time of up to approximately 5 hours with an average fuel consumption of approximately 3.5 kg\/h.\u003c\/p\u003e  \u003chr data-start=\"2956\" data-end=\"2959\"\u003e  \u003ch2 data-start=\"2961\" data-end=\"2985\"\u003eTechnology \u0026amp; equipment\u003c\/h2\u003e  \u003cp data-start=\"2987\" data-end=\"3071\"\u003eThe boiler consists of welded steel boiler sheet with 40 mm mineral wool insulation.\u003c\/p\u003e  \u003cp data-start=\"3073\" data-end=\"3094\"\u003eKey features:\u003c\/p\u003e  \u003cul data-start=\"3096\" data-end=\"3368\"\u003e  \u003cli data-start=\"3096\" data-end=\"3122\"\u003e  \u003cp data-start=\"3098\" data-end=\"3122\"\u003eMetal-ceramic burner\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3123\" data-end=\"3147\"\u003e  \u003cp data-start=\"3125\" data-end=\"3147\"\u003eMovable cast iron grate\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3148\" data-end=\"3196\"\u003e  \u003cp data-start=\"3150\" data-end=\"3196\"\u003eVertical convection channels with swirl unit\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3197\" data-end=\"3224\"\u003e  \u003cp data-start=\"3199\" data-end=\"3224\"\u003eMechanical train control\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3225\" data-end=\"3264\"\u003e  \u003cp data-start=\"3227\" data-end=\"3264\"\u003eThermometer in the upper boiler area\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3265\" data-end=\"3316\"\u003e  \u003cp data-start=\"3267\" data-end=\"3316\"\u003eConnection sleeves for flow and return (38.1 mm)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3317\" data-end=\"3342\"\u003e  \u003cp data-start=\"3319\" data-end=\"3342\"\u003eDBV-1 valve connection\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3343\" data-end=\"3368\"\u003e  \u003cp data-start=\"3345\" data-end=\"3368\"\u003eexhaust connection at the rear\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3370\" data-end=\"3481\"\u003eThe required chimney draft is approximately 0.18–0.21 mbar.\u003cbr data-start=\"3430\" data-end=\"3433\"\u003eRecommended return temperature: at least 55 °C.\u003c\/p\u003e  \u003chr data-start=\"3483\" data-end=\"3486\"\u003e  \u003ch2 data-start=\"3488\" data-end=\"3509\"\u003eEfficiency \u0026amp; Environment\u003c\/h2\u003e  \u003cp data-start=\"3511\" data-end=\"3611\"\u003eThe MPM Wood Plus 14 meets the requirements of EU Regulation 2015\/1189 (Ecodesign) and achieves:\u003c\/p\u003e  \u003cul data-start=\"3613\" data-end=\"3763\"\u003e  \u003cli data-start=\"3613\" data-end=\"3649\"\u003e  \u003cp data-start=\"3615\" data-end=\"3649\"\u003eSeasonal energy efficiency: 81%\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3650\" data-end=\"3680\"\u003e  \u003cp data-start=\"3652\" data-end=\"3680\"\u003eEnergy efficiency class: A+\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3681\" data-end=\"3717\"\u003e  \u003cp data-start=\"3683\" data-end=\"3717\"\u003eEnergy Efficiency Index (EEI): 118\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3718\" data-end=\"3763\"\u003e  \u003cp data-start=\"3720\" data-end=\"3763\"\u003eEfficiency at rated power: 83.7%\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3765\" data-end=\"3810\"\u003eEmission values ​​for firewood ≤ 25% moisture content:\u003c\/p\u003e  \u003cul data-start=\"3812\" data-end=\"3891\"\u003e  \u003cli data-start=\"3812\" data-end=\"3836\"\u003e  \u003cp data-start=\"3814\" data-end=\"3836\"\u003eDust (PM): 13 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3837\" data-end=\"3854\"\u003e  \u003cp data-start=\"3839\" data-end=\"3854\"\u003eOGC: 16 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3855\" data-end=\"3872\"\u003e  \u003cp data-start=\"3857\" data-end=\"3872\"\u003eCO: 500 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"3873\" data-end=\"3891\"\u003e  \u003cp data-start=\"3875\" data-end=\"3891\"\u003eNOx: 146 mg\/m³\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"3893\" data-end=\"3986\"\u003eThe boiler complies with class 5 according to PN-EN 303-5:2021-09 and bears the CE mark (2023).\u003c\/p\u003e  \u003chr data-start=\"3988\" data-end=\"3991\"\u003e  \u003ch2 data-start=\"3993\" data-end=\"4030\"\u003ecompatibility \u0026amp; System integration\u003c\/h2\u003e  \u003cp data-start=\"4032\" data-end=\"4063\"\u003eThe wood gasification boiler is for:\u003c\/p\u003e  \u003cul data-start=\"4065\" data-end=\"4254\"\u003e  \u003cli data-start=\"4065\" data-end=\"4105\"\u003e  \u003cp data-start=\"4067\" data-end=\"4105\"\u003eopen heating systems according to PN-EN 12828\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4106\" data-end=\"4158\"\u003e  \u003cp data-start=\"4108\" data-end=\"4158\"\u003eclosed systems with membrane expansion vessel\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4159\" data-end=\"4198\"\u003e  \u003cp data-start=\"4161\" data-end=\"4198\"\u003ethermal safety valve DBV-1\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"4199\" data-end=\"4254\"\u003e  \u003cp data-start=\"4201\" data-end=\"4254\"\u003eReturn flow boost (e.g. 3- or 4-way mixing valve)\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"4256\" data-end=\"4346\"\u003eA return temperature of ≥ 55 °C is mandatory to prevent corrosion and tar formation.\u003c\/p\u003e  \u003chr data-start=\"4348\" data-end=\"4351\"\u003e  \u003ch1 data-start=\"4353\" data-end=\"4371\"\u003eTechnical data\u003c\/h1\u003e  \u003cdiv class=\"TyagGW_tableContainer\"\u003e  \u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e  \u003ctable data-start=\"4373\" data-end=\"5409\" class=\"w-fit min-w-(--thread-content-width)\"\u003e  \u003cthead data-start=\"4373\" data-end=\"4391\"\u003e  \u003ctr data-start=\"4373\" data-end=\"4391\"\u003e  \u003cth data-start=\"4373\" data-end=\"4383\" data-col-size=\"sm\" class=\"\"\u003efeature\u003c\/th\u003e  \u003cth data-start=\"4383\" data-end=\"4391\" data-col-size=\"sm\" class=\"\"\u003eValue\u003c\/th\u003e  \u003c\/tr\u003e  \u003c\/thead\u003e  \u003ctbody data-start=\"4411\" data-end=\"5409\"\u003e  \u003ctr data-start=\"4411\" data-end=\"4453\"\u003e  \u003ctd data-start=\"4411\" data-end=\"4424\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e  \u003ctd data-start=\"4424\" data-end=\"4453\" data-col-size=\"sm\"\u003eMPM Project Marcin Nykiel\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4454\" data-end=\"4479\"\u003e  \u003ctd data-start=\"4454\" data-end=\"4463\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e  \u003ctd data-start=\"4463\" data-end=\"4479\" data-col-size=\"sm\"\u003eWood Plus 14\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4480\" data-end=\"4515\"\u003e  \u003ctd data-start=\"4480\" data-end=\"4493\" data-col-size=\"sm\"\u003eProduct type\u003c\/td\u003e  \u003ctd data-start=\"4493\" data-end=\"4515\" data-col-size=\"sm\"\u003ewood gasification boiler\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4516\" data-end=\"4540\"\u003e  \u003ctd data-start=\"4516\" data-end=\"4531\" data-col-size=\"sm\"\u003eRated power\u003c\/td\u003e  \u003ctd data-start=\"4531\" data-end=\"4540\" data-col-size=\"sm\"\u003e14 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4541\" data-end=\"4578\"\u003e  \u003ctd data-start=\"4541\" data-end=\"4567\" data-col-size=\"sm\"\u003eGenerated useful heat (Pn)\u003c\/td\u003e  \u003ctd data-start=\"4567\" data-end=\"4578\" data-col-size=\"sm\"\u003e14.9 kW\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4579\" data-end=\"4610\"\u003e  \u003ctd data-start=\"4579\" data-end=\"4604\" data-col-size=\"sm\"\u003eEnergy efficiency class\u003c\/td\u003e  \u003ctd data-start=\"4604\" data-end=\"4610\" data-col-size=\"sm\"\u003eA+\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4611\" data-end=\"4648\"\u003e  \u003ctd data-start=\"4611\" data-end=\"4641\" data-col-size=\"sm\"\u003eEnergy Efficiency Index (EEI)\u003c\/td\u003e  \u003ctd data-start=\"4641\" data-end=\"4648\" data-col-size=\"sm\"\u003e118\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4649\" data-end=\"4686\"\u003e  \u003ctd data-start=\"4649\" data-end=\"4678\" data-col-size=\"sm\"\u003eSeasonal energy efficiency\u003c\/td\u003e  \u003ctd data-start=\"4678\" data-end=\"4686\" data-col-size=\"sm\"\u003e81%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4687\" data-end=\"4733\"\u003e  \u003ctd data-start=\"4687\" data-end=\"4723\" data-col-size=\"sm\"\u003eefficiency at rated power\u003c\/td\u003e  \u003ctd data-start=\"4723\" data-end=\"4733\" data-col-size=\"sm\"\u003e83.7%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4734\" data-end=\"4769\"\u003e  \u003ctd data-start=\"4734\" data-end=\"4761\" data-col-size=\"sm\"\u003eThermal efficiency\u003c\/td\u003e  \u003ctd data-start=\"4761\" data-end=\"4769\" data-col-size=\"sm\"\u003e89%\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4770\" data-end=\"4819\"\u003e  \u003ctd data-start=\"4770\" data-end=\"4785\" data-col-size=\"sm\"\u003eboiler class\u003c\/td\u003e  \u003ctd data-start=\"4785\" data-end=\"4819\" data-col-size=\"sm\"\u003eClass 5 (PN-EN 303-5:2021-09)\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4820\" data-end=\"4843\"\u003e  \u003ctd data-start=\"4820\" data-end=\"4833\" data-col-size=\"sm\"\u003eheating surface\u003c\/td\u003e  \u003ctd data-start=\"4833\" data-end=\"4843\" data-col-size=\"sm\"\u003e2.0 m²\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4844\" data-end=\"4878\"\u003e  \u003ctd data-start=\"4844\" data-end=\"4864\" data-col-size=\"sm\"\u003eLoading chamber volume\u003c\/td\u003e  \u003ctd data-start=\"4864\" data-end=\"4878\" data-col-size=\"sm\"\u003eapprox. 52 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4879\" data-end=\"4917\"\u003e  \u003ctd data-start=\"4879\" data-end=\"4901\" data-col-size=\"sm\"\u003eFuel consumption\u003c\/td\u003e  \u003ctd data-start=\"4901\" data-end=\"4917\" data-col-size=\"sm\"\u003eapprox. 3.5 kg\/h\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4918\" data-end=\"4942\"\u003e  \u003ctd data-start=\"4918\" data-end=\"4931\" data-col-size=\"sm\"\u003eBurning time\u003c\/td\u003e  \u003ctd data-start=\"4931\" data-end=\"4942\" data-col-size=\"sm\"\u003eapprox. 5 hours\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4943\" data-end=\"4977\"\u003e  \u003ctd data-start=\"4943\" data-end=\"4967\" data-col-size=\"sm\"\u003eWater quantity in the boiler\u003c\/td\u003e  \u003ctd data-start=\"4967\" data-end=\"4977\" data-col-size=\"sm\"\u003e74 dm³\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"4978\" data-end=\"5010\"\u003e  \u003ctd data-start=\"4978\" data-end=\"4999\" data-col-size=\"sm\"\u003eMax. operating pressure\u003c\/td\u003e  \u003ctd data-start=\"4999\" data-end=\"5010\" data-col-size=\"sm\"\u003e1.5 bar\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5011\" data-end=\"5044\"\u003e  \u003ctd data-start=\"5011\" data-end=\"5032\" data-col-size=\"sm\"\u003eOperating temperature\u003c\/td\u003e  \u003ctd data-start=\"5032\" data-end=\"5044\" data-col-size=\"sm\"\u003e60–90 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5045\" data-end=\"5084\"\u003e  \u003ctd data-start=\"5045\" data-end=\"5075\" data-col-size=\"sm\"\u003eMinimum return temperature\u003c\/td\u003e  \u003ctd data-start=\"5075\" data-end=\"5084\" data-col-size=\"sm\"\u003e55 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5085\" data-end=\"5117\"\u003e  \u003ctd data-start=\"5085\" data-end=\"5103\" data-col-size=\"sm\"\u003eExhaust gas temperature\u003c\/td\u003e  \u003ctd data-start=\"5103\" data-end=\"5117\" data-col-size=\"sm\"\u003e125–140 °C\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5118\" data-end=\"5148\"\u003e  \u003ctd data-start=\"5118\" data-end=\"5137\" data-col-size=\"sm\"\u003eExhaust gas mass flow\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5137\" data-end=\"5148\"\u003e9.1 g\/s\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5149\" data-end=\"5187\"\u003e  \u003ctd data-start=\"5149\" data-end=\"5176\" data-col-size=\"sm\"\u003eFlow\/return diameter\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5176\" data-end=\"5187\"\u003e38.1 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5188\" data-end=\"5206\"\u003e  \u003ctd data-start=\"5188\" data-end=\"5195\" data-col-size=\"sm\"\u003eHeight\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5195\" data-end=\"5206\"\u003e1100 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5207\" data-end=\"5234\"\u003e  \u003ctd data-start=\"5207\" data-end=\"5224\" data-col-size=\"sm\"\u003eWide cases\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5224\" data-end=\"5234\"\u003e480 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5235\" data-end=\"5260\"\u003e  \u003ctd data-start=\"5235\" data-end=\"5250\" data-col-size=\"sm\"\u003eTotal width\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5250\" data-end=\"5260\"\u003e585 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5261\" data-end=\"5286\"\u003e  \u003ctd data-start=\"5261\" data-end=\"5275\" data-col-size=\"sm\"\u003eTotal length\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5275\" data-end=\"5286\"\u003e1105 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5287\" data-end=\"5311\"\u003e  \u003ctd data-start=\"5287\" data-end=\"5297\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5297\" data-end=\"5311\"\u003eapprox.300 kg\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5312\" data-end=\"5375\"\u003e  \u003ctd data-start=\"5312\" data-end=\"5345\" data-col-size=\"sm\"\u003eMinimum chimney cross-section\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5345\" data-end=\"5375\"\u003e180 x 180 mm or Ø 178 mm\u003c\/td\u003e  \u003c\/tr\u003e  \u003ctr data-start=\"5376\" data-end=\"5409\"\u003e  \u003ctd data-start=\"5376\" data-end=\"5402\" data-col-size=\"sm\"\u003eMinimum chimney height\u003c\/td\u003e  \u003ctd data-col-size=\"sm\" data-start=\"5402\" data-end=\"5409\"\u003e7 m\u003c\/td\u003e  \u003c\/tr\u003e  \u003c\/tbody\u003e  \u003c\/table\u003e  \u003c\/div\u003e  \u003c\/div\u003e  \u003chr data-start=\"5411\" data-end=\"5414\"\u003e  \u003ch2 data-start=\"5416\" data-end=\"5431\"\u003eScope of delivery\u003c\/h2\u003e  \u003cul data-start=\"5433\" data-end=\"5511\"\u003e  \u003cli data-start=\"5433\" data-end=\"5464\"\u003e  \u003cp data-start=\"5435\" data-end=\"5464\"\u003eMPM Wood Plus 14 boiler\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5465\" data-end=\"5488\"\u003e  \u003cp data-start=\"5467\" data-end=\"5488\"\u003eUser manual\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5489\" data-end=\"5511\"\u003e  \u003cp data-start=\"5491\" data-end=\"5511\"\u003eWarranty documents\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003chr data-start=\"5513\" data-end=\"5516\"\u003e  \u003ch2 data-start=\"5518\" data-end=\"5557\"\u003eAccessories\/Recommendation (Cross-selling)\u003c\/h2\u003e  \u003cp data-start=\"5559\" data-end=\"5621\"\u003eFor compliant and long-lasting operation, we recommend:\u003c\/p\u003e  \u003cul data-start=\"5623\" data-end=\"5840\"\u003e  \u003cli data-start=\"5623\" data-end=\"5663\"\u003e  \u003cp data-start=\"5625\" data-end=\"5663\"\u003eBuffer tank 800 liters or larger\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5664\" data-end=\"5703\"\u003e  \u003cp data-start=\"5666\" data-end=\"5703\"\u003eThermal safety valve DBV-1\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5704\" data-end=\"5761\"\u003e  \u003cp data-start=\"5706\" data-end=\"5761\"\u003eReturn temperature boost (thermostatic mixing valve 55 °C)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5762\" data-end=\"5798\"\u003e  \u003cp data-start=\"5764\" data-end=\"5798\"\u003eDraft regulator for the chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"5799\" data-end=\"5840\"\u003e  \u003cp data-start=\"5801\" data-end=\"5840\"\u003eAcid-resistant stainless steel chimney\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"5842\" data-end=\"5928\"\u003eSuitable buffer tanks and safety groups can be found at:\u003cbr data-start=\"5906\" data-end=\"5909\"\u003e\u003ca data-start=\"5909\" data-end=\"5928\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/gemashop.de\"\u003ehttps:\/\/gemashop.de\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-eri7ssmm.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e  \u003chr data-start=\"5930\" data-end=\"5933\"\u003e  \u003ch2 data-start=\"5935\" data-end=\"5968\"\u003eAssembly \u0026amp; Safety instructions\u003c\/h2\u003e  \u003cul data-start=\"5970\" data-end=\"6250\"\u003e  \u003cli data-start=\"5970\" data-end=\"6034\"\u003e  \u003cp data-start=\"5972\" data-end=\"6034\"\u003eInstallation exclusively by a qualified specialist company\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6035\" data-end=\"6092\"\u003e  \u003cp data-start=\"6037\" data-end=\"6092\"\u003eOnly use dry firewood (≤ 25% moisture)\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6093\" data-end=\"6132\"\u003e  \u003cp data-start=\"6095\" data-end=\"6132\"\u003eReturn temperature at least 55 °C\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6133\" data-end=\"6169\"\u003e  \u003cp data-start=\"6135\" data-end=\"6169\"\u003eNo operation without a buffer tank\u003c\/p\u003e  \u003c\/li\u003e  \u003cli data-start=\"6170\" data-end=\"6250\"\u003e  \u003cp data-start=\"6172\" data-end=\"6250\"\u003eNo burning of plastic, treated wood or liquid fuels\u003c\/p\u003e  \u003c\/li\u003e  \u003c\/ul\u003e  \u003cp data-start=\"6252\" data-end=\"6311\"\u003eImproper operation will result in the loss of warranty.\u003c\/p\u003e  \u003chr data-start=\"6313\" data-end=\"6316\"\u003e  \u003ch2 data-start=\"6318\" data-end=\"6324\"\u003eFAQ\u003c\/h2\u003e  \u003cp data-start=\"6326\" data-end=\"6453\"\u003e\u003cstrong data-start=\"6326\" data-end=\"6368\"\u003e1. Which fuels are permitted?\u003c\/strong\u003e\u003cbr data-start=\"6368\" data-end=\"6371\"\u003eFirewood with a residual moisture content of ≤ 25%. Other fuels are not permitted.\u003c\/p\u003e  \u003cp data-start=\"6455\" data-end=\"6588\"\u003e\u003cstrong data-start=\"6455\" data-end=\"6493\"\u003e2. Is a buffer storage tank mandatory?\u003c\/strong\u003e\u003cbr data-start=\"6493\" data-end=\"6496\"\u003eYes. Operation is only permitted with a buffer tank. According to the product data sheet, at least 800 liters.\u003c\/p\u003e  \u003cp data-start=\"6590\" data-end=\"6751\"\u003e\u003cstrong data-start=\"6590\" data-end=\"6660\"\u003e3. Can the boiler be operated in a closed system?\u003c\/strong\u003e\u003cbr data-start=\"6660\" data-end=\"6663\"\u003eYes, with a diaphragm expansion vessel, safety valve and thermal protection (e.g. DBV-1).\u003c\/p\u003e  \u003cp data-start=\"6753\" data-end=\"6833\"\u003e\u003cstrong data-start=\"6753\" data-end=\"6805\"\u003e4. What energy efficiency class does the boiler have?\u003c\/strong\u003e\u003cbr data-start=\"6805\" data-end=\"6808\"\u003eA+ with an EEI of 118.\u003c\/p\u003e  \u003cp data-start=\"6835\" data-end=\"6958\"\u003e\u003cstrong data-start=\"6835\" data-end=\"6893\"\u003e5. What is the minimum return temperature required?\u003c\/strong\u003e\u003cbr data-start=\"6893\" data-end=\"6896\"\u003eAt least 55 °C to prevent corrosion and tar formation.\u003c\/p\u003e  \u003cp data-start=\"6960\" data-end=\"7106\"\u003e\u003cstrong data-start=\"6960\" data-end=\"7006\"\u003e6. What are the chimney requirements?\u003c\/strong\u003e\u003cbr data-start=\"7006\" data-end=\"7009\"\u003eMinimum cross-section 180 x 180 mm or Ø 178 mm, minimum height 7 m, required tension approx. 0.20 mbar.\u003c\/p\u003e  \u003chr data-start=\"7108\" data-end=\"7111\"\u003e  \u003ch2 data-start=\"7113\" data-end=\"7121\"\u003eConclusion\u003c\/h2\u003e  \u003cp data-start=\"7123\" data-end=\"7384\"\u003eThe MPM Wood Plus 14 wood gasification boiler is a technically sophisticated solution for efficient heating with logs. With Class 5, Ecodesign compliance, and an A+ energy rating, it offers a sustainable and high-performance heating solution for modern heating systems with buffer storage.\u003c\/p\u003e  \u003cp data-start=\"7386\" data-end=\"7447\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eOrder now and modernize your heating technology efficiently.\u003c\/p\u003e","brand":"MPM","offers":[{"title":"Default Title","offer_id":56653812859228,"sku":"MPMWP14","price":2306.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/mpm-wood-plus-14-kw-holzvergaserkessel-a-klasse-5-o178-holzvergaserkessel-5655773.webp?v=1770944058","url":"https:\/\/mt.gemashop.de\/fi\/products\/mpm-wood-plus-14-wood-carburettor-boiler-14kw-1","provider":"GEMA Shop","version":"1.0","type":"link"}