{"product_id":"kohlevergaser-atmos-kc-35-s-35-kw","title":"Atmos KC35S Coal Gasifier 35 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026 Application\u003c\/h2\u003e \u003cp\u003eThe Atmos KC 35 S coal gasifier is a manually fed hot water boiler with 35 kW rated heat output for heating systems designed to use lignite briquettes as the primary fuel. It is suitable for buildings with a corresponding heat demand and is typically integrated into a water-based central heating system with a buffer tank.\u003c\/p\u003e \u003cp\u003eDry split logs can be used as an alternative fuel. The boiler output, chimney, return temperature boost, and buffer tank should always be sized appropriately for the system.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026 Equipment\u003c\/h2\u003e \u003cp\u003eThe boiler operates on the principle of downdraft gasification with an induced draft fan. The boiler casing is made of welded steel sheets, the lower secondary combustion chamber is lined with ceramic, and the air supply is managed via primary and secondary air inlets.\u003c\/p\u003e \u003cp\u003eStandard equipment includes an electromechanical control unit, a Honeywell FR 124 draft regulator, a boiler thermostat, a flue gas thermostat, a safety thermostat, and a cooling coil to prevent overheating. The rotating grate mechanism supports operation with coal and wood as an alternative fuel.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Advantages\u003c\/h2\u003e \u003cp\u003eThe Atmos KC 35 S is designed for practical, robust heating operation with manually fed solid fuel. The induced draft fan supports the combustion process and reduces smoke development in the operating area when refueling.\u003c\/p\u003e \u003cp\u003eThe combination of a ceramic-lined combustion chamber, preheated air supply, and mechanical grate technology makes this boiler appealing to operators seeking a classic solid fuel boiler with a clear technical design.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026 Compatibility\u003c\/h2\u003e \u003cp\u003eOperation requires integration with a return temperature boost system to achieve the necessary return water temperature. The boiler outlet temperature during operation ranges from 80 to 90 °C.\u003c\/p\u003e \u003cp\u003eInstallation with a buffer tank is intended for system operation. Additionally, chimney draft, flue gas routing, combustion air supply, and safety components must be planned and executed to match the heating system.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Specifications at a Glance\u003c\/h2\u003e \u003cp\u003eAn overview of the key technical data for the Atmos KC 35 S.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated Output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e35 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eLignite briquettes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCombustion Technology\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eDowndraft gasification with induced draft fan\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90.3 %\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEnergy Efficiency Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Flow Temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e90 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Operating Pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eLog Length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e330 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBoiler Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDraft Requirement\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e24 Pa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Gas Temperature\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e209 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Pipe Connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e150\/152 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eSafety Heat Exchanger\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eCooling coil to prevent overheating included\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBuffer Tank Recommended\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1435 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWidth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e675 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDepth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e758 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower Consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 W\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation is carried out as part of a water-based heating system with a suitable return temperature boost, flue gas routing, combustion air supply, and safety equipment. The boiler is intended for placement in a suitable boiler room and requires coordinated integration with the chimney, buffer tank, and heating circuit.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe primary fuel is lignite briquettes. Dry split logs can be used as an alternative fuel. For consistently clean operation, fuel quality, chimney draft, return water temperature, regular cleaning, and professional commissioning are crucial.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of Delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eAtmos KC 35 S coal gasifier\u003c\/li\u003e \u003cli\u003eSteel brush with accessories\u003c\/li\u003e \u003cli\u003ePoker\u003c\/li\u003e \u003cli\u003eFilling valve\u003c\/li\u003e \u003cli\u003eOperating and maintenance manual\u003c\/li\u003e \u003cli\u003eHoneywell FR 124 draft regulator\u003c\/li\u003e \u003cli\u003eAsh container\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Atmos","offers":[{"title":"Default Title","offer_id":49417084830044,"sku":"01.12.35","price":4671.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/atmos-kc-35-s-kohlevergaser-35-kw-heizkessel-fur-braunkohlebriketts-8173353.webp?v=1770692665","url":"https:\/\/mt.gemashop.de\/hr\/products\/coal-gasifier-atmos-kc-35-s-35-kw","provider":"GEMA Shop","version":"1.0","type":"link"}