{"product_id":"kohlevergaserkessel-atmos-kc16s-18-kw","title":"ATMOS KC16S coal gasification boiler 18 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026 Application\u003c\/h2\u003e \u003cp\u003eThe ATMOS KC16S coal gasifier is a manually fed hot water boiler designed for lignite briquettes and intended for heating family homes, weekend houses, and similar properties. The model operates with a boiler heat output of 18 kW and can also use dry split logs as an alternative fuel. This makes the boiler suitable for operators looking for a robust solid fuel boiler with classic manual feeding and water-based integration.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026 Equipment\u003c\/h2\u003e \u003cp\u003eThe boiler body is a welded steel construction and operates on the principle of downdraft gasification with an induced draft fan. Ceramic moldings are used in the lower combustion chamber, while the rotating grate mechanism with secondary air supply supports combustion and facilitates ash removal. The equipment includes a thermometer, boiler thermostat, flue gas thermostat, safety thermostat, and a cooling loop to prevent overheating. Primary and secondary air can be adjusted separately, allowing adaptation to the fuel and operating conditions.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Advantages\u003c\/h2\u003e \u003cp\u003eIn daily operation, the KC16S scores with clear, mechanically straightforward boiler technology. The induced draft fan helps reduce smoke when refueling, and the grate mechanism aids in removing ash during operation. For the user, this means straightforward operation with robust technology, easily accessible cleaning areas, and a design tailored for classic use with lignite briquettes.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026 Compatibility\u003c\/h2\u003e \u003cp\u003eThe boiler is designed for integration into a water-based heating system and requires a professionally designed chimney as well as a boiler room with an adequate combustion air supply. The documentation specifies a minimum required return temperature of 65 °C and a boiler operating range of 80 to 90 °C. For low-corrosion operation, the manufacturer describes integration with return temperature boosting, e.g., via a Laddomat 22 or a suitable thermostatic control valve; additionally, combining it with buffer tanks is described as a sensible system solution.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical Data at a Glance\u003c\/h2\u003e \u003cp\u003eThe key confirmed specifications of the ATMOS KC16S in a compact overview.\u003c\/p\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRated Output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e18 kW\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eLignite briquettes\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eCombustion Technology\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eDowndraft gasification with induced draft fan\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEfficiency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e88.5 %\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eEnergy Efficiency Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003eC\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Operating Pressure\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eBoiler Class\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e5\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eRequired Chimney Draft\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e16 Pa\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Gas Temperature at Rated Output\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e165 °C\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFlue Pipe Connection\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e150\/152 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eMax. Log Length\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eHeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e1166 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWidth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e675 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eDepth\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e658 mm\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eVoltage\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e230 V\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eFrequency\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 Hz\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003ePower Consumption\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e50 W\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e \u003ctd class=\"product-th__value\"\u003e275 kg\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eInstallation\u003c\/h2\u003e \u003cp\u003eInstallation must be planned for a boiler room with adequate combustion air; the manual specifies an opening of at least 300 cm² for systems from 15 to 75 kW. The connection to the chimney, flue duct, heating system, and power supply must be carried out professionally. For operation, return temperature boosting and protection against overheating must be considered; the manufacturer also recommends a concrete or steel foundation under the boiler.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eThe KC16S is designed for lignite briquettes; dry split logs serve as an alternative fuel. During operation, doors, covers, and the start-up flap must be operated in the intended position, and the boiler must be cleaned regularly to maintain performance and service life. The documentation also specifies an annual technical inspection of the boiler room and exhaust system, as well as a CE declaration of conformity for the series.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of Delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eATMOS KC16S coal gasification boiler\u003c\/li\u003e \u003cli\u003eSteel brush with accessories\u003c\/li\u003e \u003cli\u003ePoker\u003c\/li\u003e \u003cli\u003eFilling valve\u003c\/li\u003e \u003cli\u003eOperating and maintenance manual\u003c\/li\u003e \u003cli\u003eHoneywell FR 124 draft regulator\u003c\/li\u003e \u003cli\u003eAsh container\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Atmos","offers":[{"title":"Default Title","offer_id":49417012805980,"sku":"01.12.16","price":3510.49,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/atmos-kc-16-s-kohlevergaser-18-kw-vergaserkessel-fur-braunkohlebriketts-7460345.webp?v=1770692600","url":"https:\/\/mt.gemashop.de\/products\/atmos-kc16s-18-kw-coal-gasifier-boiler","provider":"GEMA Shop","version":"1.0","type":"link"}