Product Overview & Application Area
The ATTACK SLX 45 PROFI is a manually fed wood gasification boiler for closed hot water heating systems. With a nominal output of 45 kW and an output range of 22.5 to 45 kW, this model is intended for larger central heating systems whose heat demand has been professionally matched to the boiler output.
The 230-liter filling chamber accommodates dry, split firewood with a length of up to 750 mm. The generously sized fuel chamber allows for longer logs and reduces the effort required for splitting and reloading fuel.
Technology & Equipment
The temperature-controlled PROFI PID controller records boiler and flue gas temperatures, modulates the speed of the induced draft fan, and controls the heating circuit pump. An additional controller output can be used optionally for a domestic hot water or buffer storage loading pump.
In the PROFI version, primary and secondary air are mechanically preset. The boiler operates without a lambda sensor. A tubular heat exchanger with turbulators supports heat transfer to the heating water. The integrated safety heat exchanger, together with a suitable thermal drain safety device, enables the dissipation of excess heat.
Everyday Benefits
The large filling chamber and the maximum log length of 750 mm allow the use of long logs. With suitable fuel quality, nominal operation, and a correctly matched system, the approximate burn time is about 5.1 hours per load.
The PROFI controller combines clear temperature monitoring with modulating fan control. Pump functions can be set according to the planned hydraulics, while combustion air is adjusted via the mechanical basic setting.
System Integration & Compatibility
For the ATTACK SLX 45 PROFI, a buffer tank volume of 3,200 liters is recommended. The final sizing depends on the heating load, system hydraulics, heat draw, operating mode, and the technical requirements of the respective building.
The flow and return connections are designed as G-2-inch connections. The flue pipe connection has a diameter of 150 mm, and the required chimney draft is 23 Pa. A suitable return temperature boost must ensure a return temperature of at least 65 °C.
Technical data at a glance
| Nominal output |
45 kW |
| Fuel |
Dry, split firewood |
| Combustion technology |
Wood gasifier |
| Fuel efficiency at nominal output |
81.1% |
| Seasonal space heating energy efficiency |
79% |
| Energy efficiency class |
A+ |
| Energy efficiency index |
EEI 115 |
| Boiler class |
Class 5 |
| Maximum log length |
750 mm |
| Flue gas temperature at rated load |
170 °C |
| Required chimney draft |
23 Pa |
| Flue pipe connection |
150 mm |
| Flow and return |
G 2 inch |
| Safety heat exchanger |
Yes |
| Lambda sensor |
No |
| Maximum operating overpressure |
2.5 bar |
| Recommended buffer tank volume |
3,200 liters |
| Electrical connection |
230 V / 50 Hz / 10 A |
| Auxiliary power at rated output |
61 W |
| Protection class |
IP20 |
| Dimensions H × W × D |
1,472 × 703 × 1,506 mm |
| Weight |
650 kg |
Installation
Installation, hydraulic connection, chimney connection, electrical connection, initial commissioning, and safety inspection must be carried out by appropriately qualified professionals. The system requires an effective return temperature raising device, a properly sized buffer tank, a safety valve, a thermal drain safety device, and a permanently secured heat dissipation.
Notes
For proper operation, dry, split firewood with a recommended wood moisture content of approximately 12 to 20 % must be used. Wet or unsuitable fuel can impair performance and combustion quality and promote the formation of tar and condensate.
The required boiler output, buffer tank size, system hydraulics and chimney design must be determined on a project-specific basis. The output specifications do not replace a heat load calculation or professional planning.
Scope of delivery
- ATTACK SLX 45 PROFI wood gasification boiler with integrated PROFI-PID control