{"product_id":"holzvergaserkessel-attack-slx-50-lambda-touch","title":"Wood gasification boiler ATTACK SLX 50 LAMBDA Touch 50 kW","description":"\u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eProduct Overview \u0026amp; Area of Application\u003c\/h2\u003e \u003cp\u003eThe ATTACK SLX 50 LAMBDA Touch is a manually fed wood gasification boiler for closed hot water heating systems. With a nominal output of 50 kW and an output range of 25 to 50 kW, this model is intended for larger central heating systems whose heat demand has been professionally matched to the boiler output.\u003c\/p\u003e \u003cp\u003eThe 230-liter filling chamber accommodates dry, split firewood with a length of up to 750 mm. The generously sized fuel chamber allows the use of long logs and reduces the effort required for splitting and reloading fuel.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eTechnology \u0026amp; Equipment\u003c\/h2\u003e \u003cp\u003eThe LAMBDA Touch control processes boiler temperature, flue gas temperature, and residual oxygen content. Based on these measured values, it controls the induced draft fan as well as the motorized primary and secondary air dampers. The combustion air is thus automatically adjusted to the current operating state.\u003c\/p\u003e \u003cp\u003eA tubular heat exchanger with turbulators supports heat transfer to the heating water. The integrated safety heat exchanger, together with a suitable thermal drain safety device, enables the dissipation of excess heat in the event of an impermissibly high boiler temperature.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eEveryday Benefits\u003c\/h2\u003e \u003cp\u003eThe large filling chamber and the maximum log length of 750 mm allow the use of long logs. With suitable fuel quality, nominal operation, and a correctly matched system, the approximate burn time is about 4.6 hours per fill.\u003c\/p\u003e \u003cp\u003eTouchscreen, lambda sensor, and motorized air dampers support controlled combustion. The automatic combustion control reduces the need for manual adjustments to the primary and secondary air during operation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eSystem Integration \u0026amp; Compatibility\u003c\/h2\u003e \u003cp\u003eFor the ATTACK SLX 50 LAMBDA Touch, a buffer tank volume of 3,500 liters is recommended. The final sizing depends on the heating load, system hydraulics, heat consumption, operating mode, and the technical requirements of the respective building.\u003c\/p\u003e \u003cp\u003eThe flow and return connections are designed as G-2-inch connections. The flue pipe connection has a diameter of 150 mm, and the required chimney draft is 23 Pa. A suitable return temperature boost must ensure a return temperature of at least 65 °C.\u003c\/p\u003e \u003c\/div\u003e \u003cstyle\u003e .product-th{margin-top:2rem}.product-th h2{margin:0 0 1rem}.product-th__table{width:100%;border-collapse:separate;border-spacing:0}.product-th__table td{padding:.95rem 1rem;vertical-align:top}.product-th__label{font-weight:700;width:38%;color:#213670}.product-th__value{color:#1f2937}.product-th__table tr:nth-child(odd) td{background:#f4f7fb}.product-th__table tr:nth-child(even) td{background:#fafbfd} \u003c\/style\u003e \u003cdiv class=\"product-th\"\u003e \u003ch2\u003eTechnical data at a glance\u003c\/h2\u003e \u003ctable class=\"product-th__table\"\u003e \u003ctbody\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eNominal output stage\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e50 kW\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eOutput range\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e25–50 kW\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFuel\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eDry, split firewood\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eCombustion technology\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eWood gasification boiler\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFuel efficiency at rated output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e85.0%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSeasonal space heating energy efficiency\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e82%\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eA+\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eEnergy efficiency index\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eEEI 121\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eBoiler class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eClass 5\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMaximum log length\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e750 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLoading chamber volume\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e230 liters\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue gas temperature at nominal load\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e170 °C\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRequired chimney draft\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e23 Pa\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlue pipe connection\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e150 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eFlow and return\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eG 2 inch\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eSafety heat exchanger\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eLambda sensor\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eMaximum operating overpressure\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eRecommended buffer tank volume\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e3,500 liters\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eElectrical connection\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e230 V \/ 50 Hz \/ 10 A\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eAuxiliary power at rated output\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e67 W\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eProtection class\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eDimensions H × W × D\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e1,472 × 703 × 1,506 mm\u003c\/td\u003e\n\u003c\/tr\u003e \u003ctr\u003e\n\u003ctd class=\"product-th__label\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"product-th__value\"\u003e650 kg\u003c\/td\u003e\n\u003c\/tr\u003e \u003c\/tbody\u003e \u003c\/table\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eAssembly\u003c\/h2\u003e \u003cp\u003eInstallation, hydraulic connection, chimney connection, electrical connection, initial commissioning, and safety inspection must be carried out by appropriately qualified specialists. The system requires effective return temperature boosting, a properly sized buffer tank, a safety valve, a thermal drain safety device, and a permanently secured heat dissipation.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eNotes\u003c\/h2\u003e \u003cp\u003eFor proper operation, dry, split firewood with a recommended moisture content of approximately 12 to 20% must be used. Wet or unsuitable fuel can impair performance and combustion quality and promote tar and condensate formation.\u003c\/p\u003e \u003cp\u003eThe required boiler output, buffer tank size, system hydraulics, and chimney design must be determined on a project-specific basis. The performance data does not replace a heat load calculation or professional planning.\u003c\/p\u003e \u003c\/div\u003e \u003cdiv class=\"gema-section\"\u003e \u003ch2\u003eScope of delivery\u003c\/h2\u003e \u003cul\u003e \u003cli\u003eATTACK SLX 50 LAMBDA Touch wood gasification boiler with integrated LAMBDA Touch control and lambda sensor\u003c\/li\u003e \u003c\/ul\u003e \u003c\/div\u003e","brand":"Attack","offers":[{"title":"Default Title","offer_id":49552736878940,"sku":"ASLXL50","price":5998.07,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0757\/7796\/6428\/files\/attack-slx-profi-holzvergaserkessel-frontansicht_07fadf77-cdc1-424d-8a20-740f5eb5b95d.jpg?v=1785919075","url":"https:\/\/mt.gemashop.de\/products\/holzvergaserkessel-attack-slx-50-lambda-touch","provider":"GEMA Shop","version":"1.0","type":"link"}