Master V.3 PLUS/EU-i-3 PLUS heating control for 3 heating circuits mixed and unmixed
Master V.3 PLUS/EU-i-3 PLUS heating control for 3 heating circuits mixed and unmixed is in stock and will be shipped as soon as it is available again
Delivery and shipping
Delivery and shipping
Processing time is typically 1 business day. Delivery for parcels is 1-3 business days. For freight forwarding, delivery time is 3-5 business days. Delivery times outside Germany vary.
Description
Description
Master V.3 PLUS/EU-i-3 PLUS Open Therm heating control for 3 heating circuits mixed and unmixed
Special features:
- smooth control of three mixing valves
- Control of the hot water pump
- supports a solar system
- Return temperature protection
- Weather and weekly control
- affordable by solar-more
- two configured potential-free outputs
- two configured voltage outputs
- two configurable 0-10V outputs (PLUS VERSION)
- Solar pump output with PWM signal (PLUS VERSION)
- Cascade connection of 4 heat generators (PLUS VERSION)
- Communication of three two-point room thermostats
- Communication with a room thermostat with RS communication
- Extension of an EU-505 or EU-WIFI-RS module
- Control of two additional valves using additional modules EU-I-1-M, EU-I-1, EU-i-1 WW
- Updating the program version via a USB port
- OpenTherm (OT)
Technical data:
- Boiler temperature setting range - from 10 to 99°C
- Floor temperature setting range - from 10 to 50°C
- Hot water temperature setting range - 5 to 80°C
- Mains voltage 230V/50Hz
- Rated load of the outputs 0.5A
- Fuse 6.3A
- Temperature resistance of the sensors - from -30 to 99°C
Equipment
- LCD display
- Boiler temperature sensor
- Flow temperature sensor
- Return temperature sensor
- Solar sensor
- Outdoor sensor
- Wall mounting
- Sensors of type KTY 81-210 with a diameter of 5mm are used here